G R E E N T E C H

Loading...

visit our location:
65 rue des Navigateurs - Saint-Gilles les Bains
Opening Hours:
Monday to Friday, 8am - 5pm
Send us mail
contact@greentech.re
Phone Number
+262(0)262 010 317
CONTACT US

Material resources

Network analyzer (Chauvin Arnoux, PEL 103)

This equipment measures and records single-phase, two-phase and three-phase electrical power and energy. Voltage measurement ranges from 0 to 1,000 V and current from 50 mA to 10,000 A, depending on the measuring toroid used. AC measurements are RMS with 128 samples/cycle at 50 Hz and enable calculation of active, apparent and reactive power, as well as power factor. This equipment integrates the display of the first 50 harmonics to calculate THD in voltage and current.

Power recorder (OMEGAWATT Multichannel)

This equipment is used to measure active electrical power. It consists of a multi-channel concentrator combined with one or more multi-channel modules. Each module is equipped with 6 current measurement cores. The concentrator is used to take blood pressure. The characteristics of the cores used are listed below:

Temperature and relative humidity measurement

Mini data logger for air temperature and humidity - Testo 174 H set

The Testo 174H mini data logger features internal sensors to measure air temperature and humidity. Its humidity sensor is a long-term stable Testo capacitive humidity sensor, operating with an accuracy of up to ± 3%rh for air humidity measurements. The internal NTC temperature sensor is particularly precise, with an accuracy of ± 0.5°C, and covers a measurement range from -20 to +70°C.

Contact temperature measurement - TMC6 probe - H - STAINLESS STEEL

PVC/PVC cable, length 1.80 m, Ø 4 mm
Tube Ø 6 mm, length 50 mm
Temperature range: -40 °C to +120 °C
T° measurement accuracy: ±0.5 °C at +20 °C

Kit climaticien testo Smart Probes

Measurement of ambient and surface temperature, humidity, air velocity and volumetric flow rate Measurement menus for volumetric flow measurement in the duct and at the outlet, mold detection, easy-to-read illustrated documentation with IR temperature measurement value and measurement spot marking Display measurement data in graphical or tabular form, analyze and send via the testo Smart App Carry out the most important measurements on air-conditioning systems in conjunction with your smartphone/tablet

HOBO UX120-006M data logger

This equipment can record a variety of physical data via four external inputs. The four external channels accept a variety of sensors, including temperature and AC current sensors, as well as 4-20 mA and voltage input cables (sold separately).

The recorder can also calculate minimum, maximum, average and standard deviation statistics. It features a built-in LCD display to check current data in real time and monitor recording, battery wear and memory consumption between measurements.

Ultrasonic flowmeter - Ultrasonic flowmeter Fuji Electri.

This portable ultrasonic flowmeter consists of two clamp-on pipe sensors (FSS) and a digital converter (FSC) running on internal battery or mains power.

This non-invasive Portaflow-C ultrasonic flowmeter uses transit time ultrasonic signal technology to measure liquid flow in any size of pipe. It offers a wide range of applications thanks to its ability to adapt to all types of conditions and a wide choice of liquids and pipe sizes. c- Portaflow-C

Luxmeter

Luxmeter Chauvin Arnoux CA 1110. The CA 1110 luxmeter measures illuminance from all light sources (LED, Fluorescent, etc.) up to 200,000 lux in compliance with class C of standard NF C 42-710.

Weather stations

Green Tech has several weather stations across Reunion Island recording the following data at 10-minute intervals:
- Radiation
- Temperature
- Humidity
- Rainfall
- Wind speed
- Wind direction
- Pressure